Introduction
Storage channel: turret-type layered sub-storage design.
Refrigerated quantity: Max 200/400 bottles of solder paste in a single can,
The capacity of the syringe must be confirmed according to the product specifications.
Applicable varieties: No limit to model type storage.
Applicable packaging specifications: canned, syringe packed.
Temperature control: 10-20℃ (±2℃),
Temperature display: digital and temperature curve display, real-time monitoring and recording.
Feeding method: single bottle/piece continuous feeding.
Material discharging and discharging speed: The feeding/retrieving time of the discharging and discharging port is 15S/bottle.
Discharging principle: first in, first out/production date.
Secondary deposit: supports 2 and 3 deposits (can be set), and is given priority.
Equipment Parameter
ITEM | SG120P | SG400P | REMARK | |
EQUIPMENT OPERATE | Operate previlege | 4 level privilege protect | ||
Previlege Identification | finger print+IC card+password | |||
Exceptions warn method | 3 colors alarm light+buzzle | |||
Serve moudle | Bus design+absolute encoder | stable and easy to maintain | ||
Control method | PC+PLC | |||
Operate method | touchable PC operate |
REFRIGERATATION | Cooling capacity | Cans | Single,Max 100cans; | Single,Max 400cans; | canned/syringe can be mixed storage
and also storage with individual. |
Syringes | Depended on the packing specification | ||||
Refrigerated Tem. | 10~20℃ | The temperature can be set,precision,
accurancy:±2.0℃ |
|||
Storage Method | Rotating tower type layered storage design | more even of temperatue | |||
Temperature surveillance | Real-time digital display and curve graph display | Over temperature alarm | |||
Refrigeration method | Industrial compressor | Automatic defrost protection
(anti-icing) |
|||
TEMPERATURE RECOVERY | Recovery capacity | Canned,Max 15, | Canned,Max 30 | Depended on the packing specification
for syringe |
|
Temperature after recovery | 18~28℃(room tem.) | not included.silver paste | |||
Recovery Time | 0.1~99H | not included.silver paste | |||
Recovery method | automatic/manpower reserve/MES on-line instructions | not included.silver paste | |||
Fool-proofing of Recovery | If the product is not collected within the time limit, it will be utomatically returned to the refrigerated area. | not included.silver paste | |||
Mixing | Mix QTY | 1 or 2 cans | automatically counter weight | ||
Mix.Time and Speed | 1-10min;100-1000turns/min. | time/rotary speed can be adjusted. | |||
Mix Method | automatical mix,mix before taking,not mix | no need mix for syringe pack. |
Advantage:
1.The operation is simple, intuitive and convenient.
2.Cleaning squeegee quantity, short time.
3.360 degrees without dead Angle rotating cleaning.
4.Filter the paste and recycle it.
5.Automatic hot air drying.
6.Automatic hot air drying.