solder paste manage system front
solder paste manage system front
未标题-2

SOLDER PASTE STORAGE MANAGEMENT SYSTEM

Introduction

Storage channel: turret-type layered sub-storage design.

Refrigerated quantity: Max 200/400 bottles of solder paste in a single can,

The capacity of the syringe must be confirmed according to the product specifications.

Applicable varieties: No limit to model type storage.

Applicable packaging specifications: canned, syringe packed.

Temperature control: 10-20℃ (±2℃),

Temperature display: digital and temperature curve display, real-time monitoring and recording.

Feeding method: single bottle/piece continuous feeding.

Material discharging and discharging speed: The feeding/retrieving time of the discharging and discharging port is 15S/bottle.

Discharging principle: first in, first out/production date.

Secondary deposit: supports 2 and 3 deposits (can be set), and is given priority.

Equipment Parameter

ITEM SG120P SG400P REMARK
EQUIPMENT OPERATE Operate previlege 4 level privilege protect
Previlege Identification finger print+IC card+password
Exceptions warn method 3 colors alarm light+buzzle
Serve moudle Bus design+absolute encoder stable and easy to maintain
Control method PC+PLC
Operate method touchable PC operate
REFRIGERATATION Cooling capacity Cans Single,Max 100cans; Single,Max 400cans;  canned/syringe can be mixed storage

 and also storage with individual.

Syringes Depended on the packing specification
Refrigerated Tem. 1020℃ The temperature can be set,precision,

accurancy:±2.0℃

Storage Method Rotating tower type layered storage design more even of temperatue
Temperature surveillance  Real-time digital display and curve graph display Over temperature alarm
Refrigeration method Industrial compressor Automatic defrost protection

 (anti-icing)

TEMPERATURE RECOVERY Recovery capacity Canned,Max 15, Canned,Max 30 Depended on the packing specification

 for syringe

Temperature after recovery 1828℃(room tem. not included.silver paste
Recovery Time 0.1~99H not included.silver paste
Recovery method automatic/manpower reserve/MES on-line instructions not included.silver paste
Fool-proofing of Recovery If the product is not collected within the time limit, it will be utomatically returned to the refrigerated area. not included.silver paste
Mixing Mix QTY 1 or 2 cans automatically counter weight
Mix.Time and Speed 1-10min100-1000turns/min. time/rotary speed can be adjusted.
Mix Method automatical mix,mix before taking,not mix no need mix for syringe pack.

Advantage:

1.The operation is simple, intuitive and convenient.
2.Cleaning squeegee quantity, short time.
3.360 degrees without dead Angle rotating cleaning.
4.Filter the paste and recycle it.
5.Automatic hot air drying.

6.Automatic hot air drying.

 